Gas Analysis
Real time gas analysers that address the broadest application range
A compact bench-top system for real time gas and vapour analysis
Measures the concentration of gases and vapours in real time
The Hiden QGA quantitative gas analysis system is configured for continuous analysis of gases and vapours at pressures near atmosphere in standard form. Inlet accessories are available to configure the system for sampling from low to high pressures, up to 30bar.
A specialist gas analysis system for advanced research
Measures the concentration of gases and vapours in real time
The Hiden HPR-20 QIC R&D specialist gas analysis system is a bench-top mass spectrometer for the monitoring of evolved gases and vapours.
A compact bench-top system for evolved gas analysis in TGA-MS
Measures evolved gases and vapours from thermo gravimetric analysers (TGA)
The Hiden HPR-20 QIC EGA gas analysis system is configured for continuous analysis of evolved gases and vapours from thermogravimetric analysers (TGA).
HPR-20 DLS, HPR-20 EPIC, HPR-20 S1000
The specialist range of Hiden HPR-20 gas analysis systems are configured for continuous analysis of gases and vapours at pressures near atmosphere in standard form, with alternative inlet systems being offered for applications requiring direct sampling from higher pressures to 30 bar.
For ultra-high resolution & sensitivity analysis of hydrogen isotopes and light gases
The Hiden HPR-20 DLS gas analysis system is configured for continuous analysis of gases and vapours at pressures near atmosphere in standard form, alternative inlet systems being offered for applications requiring direct sampling from higher pressures to 30 bar. The mass spectrometer includes an ultra-high resolution mode specifically designed for analysis at low masses, for hydrogen isotopes and light gases.
With electron impact / electron attachment ionization modes
The Hiden HPR-20 EPIC gas analysis system is configured for continuous analysis of gases and vapours at pressures near atmosphere in standard form, alternative inlet systems being offered for applications requiring direct sampling from higher pressures to 30 bar.
With 1000 amu mass range
The Hiden HPR-20 S1000 gas analysis system configured for continuous analysis of gases and vapours at pressures near atmosphere in standard form, alternative systems being offered for applications requiring direct sampling from higher pressures to 30 bar.
MS inlets for coupling to TGA systems
Measures the decoposition and desorption gases and vapours in real time from thermal analysis systems
All of Hiden’s capillary inlet gas analysers may additionally be equipped with fast response, low dead volume interfaces for the most popular TGA equipment.
A specialist gas analysis system for fast event transient analysis
Measures the concentration of gases and vapours from low PPM to high % levels in < 0.2 seconds.
The Hiden HPR-20 QIC TMS Transient MS is configured for fast event gas analysis of gases and vapours at pressures near atmosphere. Ideal for fast gas switching experiments the MS features the Hiden QIC quartz-lined 0.9 m sampling interface.
An integrated mass spectrometer system for multi-stream fermentation off gas analysis
Measures off gas and vapour concentrations, OUR, CER, RQ from multiple reactors
The Hiden QIC BioStream is a complete, multi-stream gas composition monitoring system.Capable of analysing gas streams at flow rates from 4 ml/min up to 10 L/min. The system is suited to a range of applications including fermentation off-gas analysis, biogas production monitoring and bio-enzyme production.
A bench-top membrane inlet mass spectrometer designed for analysis of gases, vapours and VOCs in liquids
Measures dissolved gases in liquids, sea water, estuary, soil core and headspace.
The Hiden HPR-40 DSA Membrane Inlet Mass Spectrometer (MIMS) is a compact bench-top gas analysis system for real-time quantitative analysis and monitoring of dissolved/evolved gases.
Solutions for Dissolved Gas Analysis and Off-gas Analysis in Electrochemistry
The HPR 40 DSA is available with a range of DEMS cells for differential electrochemistry mass spectrometry. DEMS cells include a nano porous membrane interface for fast response in-situ determination of gaseous and volatile electrochemical reactants, reaction intermediates and products in real time.
The Hiden HPR-40 DSA Membrane Inlet Mass Spectrometer (MIMS) is a compact bench-top gas analysis system for real-time quantitative analysis and monitoring of dissolved/evolved gases.
A molecular beam sampling mass spectrometer for analysis of neutrals, radicals and ions
Measures the reaction kinetics of processes at atmospheric pressure, 5 bar option.
The Hiden HPR-60 molecular beam mass spectrometer is a compact skimmer inlet MS for the analysis of reactive gas phase intermediates.
for Discrete Low Volume Sample Analysis
Measures the concentration of gases and vapours of low volume samples.
The Hiden HPR-70 compact bench-top batch inlet gas analysis system is suitable for the analysis of discrete gas samples.
A sealed package gas analyser with integral package cracker for lamp gas analysis
Measures the concentration of gases and vapours in hermetically sealed packages
The HPR-90 automated package cracking analysis system is a complete system optimised to analyse gas within sealed volumes such as light bulbs.