Spectroscopy
Spectroscopy
For hard X-ray XPS (HAXPES) and ultra high resolution PES (ARUPS)
Features
- Handles electron energies of up to 15 keV
- Ultra high energy resolution in UPS (< 1meV), XPS (< 7 meV) and HAXPES (<15 meV)
- Angular Mapping (ΔΘ < 0.1°)
- CCD, DLD and DLD/SPIN detection available
- Low dark-count detector units
- High stability power supplies
- High retarding ratios
- Different modes of operation (UPS, XPS and HXPS)
Features
- State-of-the-art ARPES with 60° Acceptance Angle
- Optimized Lens Geometry for Non-Destructive Profiling
- Large Kinetic and Pass Energy Range
- High Energy and Angular Resolution
- Complete System Concept for Samples up to 12"
Read more: Hemispherical Energy Analyzer with Wide Angle Lens - PHOIBOS 150 WAL
Features:
- Wide Angle Pre-Lens with 44 ° Acceptance Angle
- Near Ambient Working Pressures up to 25 mbar
- Large Kinetic and Pass Energy Range
- High Energy and Angular Resolution
Read more: PHOIBOS 150 NAP Near Ambient Pressure Hemispherical Energy Analyzer
Features
- Extremely low dark counts
- Linear response due to single event counting
- 3 MHz count rate in 2D and 2D/time resolved mode
- Retrofitable on site, without changes to the analyzer
Features
- Enables Higher Resolving Power
- Increased Analyzer Performance
- Countrate up to 15 Mcps
- Facilitates Time Resolved Experiments
- Snapshot capability for fast spectrum acquisition
- Lower costs for multiplier replacements
Features
- Bolt-on solution for PHOIBOS 150
- 2 Spin components + 6 standard channels
- Based on proven “Rice University” design
- Fully integrated in SpecsLab software
Features
- Lateral resolution < 100 µm
- 12 bit digital camera with dynamic range of 1000
- High quality lens system
- Multi channel plates (MCPs) with a diameter of 40 mm
- Detector can be retrofit on site without changes to the analyzer
Features:
- Maximum (measured) count rate detectable is 16.8 Mcps (standard CEMs: 5.6 Mcps) per channel.
- Linearity and non-extended dead time behavior up to 10 Mcps true count rate. Up to these count rates no significant deviation from linearity could be observed with the PHOIBOS detection system (CEMs and PCU 300 detection electronics).
Subcategories
Detectors
PHOIBOS analyzers are equipped with a flange mounted detector assembly. The standard detector assembly consists of either one, five or nine single channel electron multipliers (SCD, MCD-5 or MCD-9). Our standard channel electron multipliers have an extended dynamic range for extremely high count rate applications.